Electric Circuits Lab
Capacitors in DC Circuits
I. Objectives:
After completing this lab experiment, you should be able to:
· Measure the resistance and capacitance.
· Familiarize with Oscilloscope and Function generator.
· Measure the RC time constant using VR and VC.
· Understand the effect of series and parallel capacitors on RC time constant.
II. Parts List:
· Resistor (1) 1 kΩ
· Capacitors (2) 0.22 µF
III. Procedures:
Part I:
1. Construct the circuit shown in Figure 1 in Mutism.
Diagram, schematic Description automatically generated
Figure 1: Series RC Circuit
2. Connect Channel A of the oscilloscope across the voltage source and Channel B across the capacitor.
3. Set the function generator to 5Vpp; 100 Hz, Square Wave 50% duty cycle with 2.5 DC offset if using a function generator . If using clock voltage, set it to 5Vpp, 100 Hz. The DC offset can be modeled by using DC mode on the oscilloscope.
4. Observe the signals on the scope screen. See Figure 2(a) below. (Use Volts/Div and Time/DIV settings to adjust the signal)
A picture containing line chart Description automatically generated
Figure 2(a): Voltage across the Voltage Source and the capacitor
5. Disable Channel A, by setting it to 0, while observing Channel B. You should be able to see the waveform as shown below. Use time base and Channel A scale to adjust the signal.
A picture containing chart Description automatically generated
Figure 2(b): Voltage across the capacitor
6. Change the time base (Sec/Div) until you have a clear waveform on the scope as shown in Figure 2(c).
A picture containing graphical user interface Description automatically generated
Figure 2(c): Voltage across the capacitor
7. Calculate the time constant of the RC circuit using the circuit parameter values. Record the result in Table 1 under calculated value.
= R*C
Calculated value
Measured value using VC
Measured value using VR
Time constant ()
220.049us
220.015us
Table 1: Calculated and measured values
8. Measuring the time constant with VC:
i. Measure the peak value of the signal, by placing one of the cursors (T1) at the peak point ___5V______.
ii. Calculate the 63% of the above value _____3.15 V____.
iii. Place the second cursor (T2) at the step (ii) value above and T1 at zero just before the capacitor voltage starts rising as shown in Figure 3.
iv. Observe the value of T2-T1 on the scope, which is the one time constant, as shown below.
v. Record the result in Table 1 above under measured value using VC.
A picture containing graphical user interface Description automatically generated
Figure 5: Measuring RC time constant using VC
9. Connect Channel B of the oscilloscope across the resistor.
10. You should be able to see the waveform as shown below. (Use Volts/Div and Time/DIV knobs to adjust the signal)
A picture containing diagram Description automatically generated
Figure 6(a): Voltage across the resistor
11. Measuring the time constant with VR:
i. Measure the peak value of the signal, by placing one of the cursors (T1) at the peak point ___5 v______.
ii. Calculate the 37% of the above value ___1.85 V______.
iii. Place the second cursor (T2) at the step (ii) value above.
iv. Observe the T2-T1 value on the scope, which is the one time constant.
v. Record the result in Table 1under measured value using VR.
Diagram Description automatically generated with medium confidence
Figure 6(b): Measuring RC time-constant using VR
Part II:
12. Place two capacitors in series as shown in Figure 7 below.
Diagram, schematic Description automatically generated
Figure 7: Series Capacitors
13. Calculate the total capacitance value and record the results in Table 2 below.
Calculated Value
Measured Value
Capacitance
11µF
10.2µF
Table 2: Series Capacitors
14. Measure the total capacitance value. Use the following procedure to measure the capacitance in Multisim.
i. Connect the impedance Meter (Simulate>>Instruments>>LabView Instruments>>Impedance Meter) as shown in Figure 8.
ii. Measure the capacitive reactance, XC, as shown in Figure 8.
iii. Calculate the capacitance using the equation, and record the value in Table 2.
Diagram, schematic Description automatically generated
Figure 8: Impedance Meter in Multisim
15. Modify the circuit as shown below, by placing two 0.22µF capacitors in series as in Figure 8.
Diagram, schematic Description automatically generated
Figure 8: RC circuit with two series capacitors
16. Calculate the new RC time constant using measured values. Record the result in Table 3 below.
Calculated value
Measured value using VR
Time constant ()
114.653 us
Table 3: Calculated and measured values
17. Connect Channel A of the oscilloscope across the resistor
18. Adjust the trigger if needed, and you should be able to see the waveform as shown in Figure 9 below.
Chart Description automatically generated
Figure 9: Voltage Across the Resistor
19. Repeat step 11. Record the measured time constant in Table 3 above.
Part III:
20. Place two capacitors in parallel as shown in Figure 10 below. ( Note: The 0.001 Ω resistor is ONLY required for simulation in Multisim. Without the resistor, the mathematical model will not converge).
Diagram, schematic Description automatically generated
Figure 10: Parallel Capacitors
21. Calculate the total capacitance value and record the results in Table 4 below.
Calculated Value
Measured Value
Capacitance
0.44µF
0.442µF
Table 4: Parallel Capacitors
22. Measure the total capacitance value. Use the following procedure to measure the capacitance in Multisim.
i. Connect the impedance Meter (Simulate>>Instruments>>LabView Instruments>>Impedance Meter).
ii. Measure the capacitive reactance.
iii. Calculate the capacitance using the equation, and record the value in Table 4.
23. Modify the circuit by placing two 0.22µF capacitors in parallel as in Figure 11.
Diagram, schematic Description automatically generated
Figure 11: RC Circuit with Parallel Capacitors
24. Calculate the new RC time constant using measured values. Record the result in Table 5 below.
25. Connect Channel A of the oscilloscope across the resistor.
26. You should be able to see the waveform as in Figure 12 below. (Use Volts/Div and Time/DIV knobs to adjust the signal)
27. Use the cursors on the oscilloscope to measure the time constant (refer to step 11). Record the result in Table 5 below under measured value.
Graphical user interface Description automatically generated with low confidence
Figure 12: Voltage across the resistor
Calculated value
Measured value using VR
Time constant ()
458.611us
For this short paper activity, you will learn about the three delays model, which explains…
Topic : Hospital adult medical surgical collaboration area a. Current Menu Analysis (5 points/5%) Analyze…
As a sales manager, you will use statistical methods to support actionable business decisions for Pastas R Us,…
Read the business intelligence articles: Getting to Know the World of Business Intelligence Business intelligence…
The behaviors of a population can put it at risk for specific health conditions. Studies…